13.Pressing UP key is forward rotation and pressing DOWN key is reverse rotation.

14.Execute JOG operation in low speed first. After the machine is running smoothly, then execute JOG operation in high speed.

15.The ratio of Load Inertia to Servo Motor Inertia (J_load /J_motor) cannot be shown in the display of JOG parameter P4-05 operation. Please press MODE key twice continuously and the users can see the ratio of Load Inertia to Servo Motor Inertia (J_load /J_motor). Then, execute JOG operation again, press MODE key once and press SET key twice to view the display on the keypad. Check if the value of J_load /J_motor is adjusted to a fixed value and displayed on the keypad after acceleration and deceleration repeatedly.

5.5.1Tuning Flowchart

Revision January 2009

5-13