Delta Electronics ASDA-B Series manual SPD1, SPD2, SPD3

Models: ASDA-B Series

1 321
Download 321 pages 45.58 Kb
Page 181
Image 181

Chapter 7 Servo ParametersASDA-B Series

P1 - 09

 

SPD1

1st Speed Command or Limit

Communication Addr.: 0109H

 

 

 

 

 

 

 

Default: 100

Related Section:

 

 

Applicable Control Mode: S/T

S mode: Section 6.3.5

 

 

Unit: rpm

 

T mode: P1-02

Range: -5000 ~ +5000

Settings:

1st Speed Command

In Speed mode, this parameter is used to set speed 1 of internal speed command.

1st Speed Limit

In Torque mode, this parameter is used to set speed limit 1 of internal speed command.

P1 - 10

SPD2

2nd Speed Command or Limit

Communication Addr.: 010AH

 

 

 

Default: 200

Related Section:

Applicable Control Mode: S/T

S mode: Section 6.3.5

Unit: rpm

 

T mode: P1-02

Range: -5000 ~ +5000

Settings:

2nd Speed Command

In Speed mode, this parameter is used to set speed 2 of internal speed command.

2nd Speed Limit

In Torque mode, this parameter is used to set speed limit 2 of internal speed command.

P1 - 11

SPD3

3rd Speed Command or Limit

Communication Addr.: 010BH

 

 

 

Default: 300

Related Section:

Applicable Control Mode: S/T

S mode: Section 6.3.5

Unit: rpm

 

T mode: P1-02

Range: -5000 ~ +5000

Settings:

3rd Speed Command

In Speed mode, this parameter is used to set speed 3 of internal speed command.

3rd Speed Limit

In Torque mode, this parameter is used to set speed limit 3 of internal speed command.

7-28