Delta Electronics ASDA-B Series manual Structure of Position Control Mode, Inhibit

Models: ASDA-B Series

1 321
Download 321 pages 45.58 Kb
Page 118
Image 118

Chapter 6 Control Modes of OperationASDA-B Series

Other setting: Reversed

Input pulse interface

Max. input pulse frequency

Line driver

500kpps

 

 

Open collector

200kpps

 

 

Logic type

0=Positive Logic

1=Negative Logic

Pulse Type

Reverse

Forward

Reverse

Forward

AB phase pulse

 

 

 

CW + CCW pulse

 

 

 

Pulse + Direction

 

 

 

6.2.2 Structure of Position Control Mode

Basic Structure:

Position Command

Position Command

Processing

Position Control Block Diagram

Speed

Loop

Current

Loop

Output Position

In order to pursue the goal of perfection in position control, the pulse signal should be modified through position command processing and the structure is shown as the figure below:

Pulse

Signal

INHIBIT

Pulse type

selection

P1-00

Electronic gear ratio (1) P1-44, P1-45

Electronic gear ratio (2) P1-15, P1-45

Low-pass

Filter P1-08

GNUM0

Revision January, 2009