Delta Electronics ASDA-B Series manual 0307H Communication Response Delay Time

Models: ASDA-B Series

1 321
Download 321 pages 45.58 Kb
Page 242
Image 242

0307H

Communication Response Delay Time

Chapter 8 MODBUS CommunicationsASDA-B Series

Default: 0

Range: 0~255

This parameter is used to delay the communication time that servo drive respond to host controller (external controller)

When the communication address is set to 255, the communication response delay time will be 0 (zero) no matter what the setting value of P3-07 is.

Revision January 2009

8-7

Page 242
Image 242
Delta Electronics ASDA-B Series manual 0307H Communication Response Delay Time