Chapter 3 Connections and WiringASDA-B Series

3.5Serial Communication Connector CN3

3.5.1 CN3 Terminal Layout and Identification

The servo drive can be connected to a PC or controller via a serial communication connector. The users can operate the servo drive through PC software supplied by Delta (contact to the dealer/distributor).

The communication connector/port of Delta servo drive can provide two common serial communication interfaces: RS-232, and RS-485 connection. RS-232 is mostly be used but is somewhat limited. The maximum cable length for an RS-232 connection is 15 meters (50 feet). Using RS-485 interface can allow longer distance for transmission and support multiple drives to be connected simultaneously.

Figure 3.9 The layout of CN3 Drive Connector:

4

1

3

6

2

5

8

 

 

 

7

 

 

CN3 Drive Connector

 

 

 

 

 

CN3 Terminal Signal Identification

 

 

 

 

 

 

Pin No

Signal Name

 

Terminal

Description

 

Identification

 

 

 

 

 

1

RS-485-

 

 

RS-485-

For data transmission of the servo drive.

 

 

Connected to the RS-485- interface of PC.

 

 

 

 

 

 

 

 

 

 

2

Signal power

 

+5VD

 

 

 

 

 

 

 

3

RS-485+

 

 

RS-485+

For data transmission of the servo drive.

 

 

Connected to the RS-485+ interface of PC.

 

 

 

 

 

 

 

 

 

 

 

4

RS-232

data

 

RS-232-RX

For data receiving of the servo drive.

 

Connected to the RS-232 interface of PC.

 

receiving

 

 

 

 

RS-232

data

 

 

For data transmission of the servo drive.

5

 

RS-232-TX

Connected to the RS-232 interface of PC.

 

transmission

 

 

Please refer to section 3.5.2.

 

 

 

 

 

 

 

 

 

 

 

 

RS-232 / RS-485

 

 

RS-232 & RS-485 data format selection

 

 

 

For RS-485 connection, connect SEL232/485(Pin6)

6

data

format

 

SEL232 / 485

 

to GND(Pin8). For RS-232 connection, do not

 

selection

 

 

 

 

 

 

 

connect SEL232/485(Pin6) to GND(Pin8).

 

 

 

 

 

 

 

 

 

 

 

7

Re-flash

 

 

Boot_Load

Boot_Load terminal for DSP Reflash burn-in

selection

 

 

selection (Do not connect this terminal).

 

 

 

 

8

Grounding

 

 

GND

 

 

 

 

 

 

 

NOTE

1)In order to avoid the communication error, if the users use their own communication connector, ensure the circuit between the connector case and all pins is not closed.

Revision January 2009

3-25

Page 50
Image 50