Chapter 7 Servo ParametersASDA-B Series

P2 - 15

 

DI6

Digital Input Terminal 6 (DI6)

Communication Addr.: 020EH

 

 

 

 

 

 

 

Default: 21

Related Section:

 

 

Applicable Control Mode: P/S/T

Section 3.3.4, Table 7.A

 

 

Unit: N/A

 

 

Range: 0 ~ 126

Settings:

See P2-10 for explanation.

P2 - 16

P2 - 17

P2 - 18

Reserved

 

Communication Addr.: 0210H

 

 

 

 

 

 

Reserved

 

Communication Addr.: 0211H

 

 

 

 

 

 

DO1

Digital Output Terminal 1 (DO1)

Communication Addr.: 0212H

 

 

 

Default: 101

Related Section:

Applicable Control Mode: P/S/T

Section 3.3.4, Table 7.B

Unit: N/A

 

Range: 0 ~ 110

 

Settings:

 

ASD-PU-01A

ASD-PU-01B

This parameter is used to determine the function and status of DO1.

DO Function Settings:

For the setting value of P2-18 ~ P2-20, please refer to Table 7.B.

DO Enabled Status Settings:

0:Normally closed (contact b)

1:Normally open (contact a)

Please re-start the servo drive after parameters have been changed.

7-44