Delta Electronics ASDA-B Series manual Name Function

Models: ASDA-B Series

1 321
Download 321 pages 45.58 Kb
Page 57
Image 57

Chapter 4 Display and OperationASDA-B Series

Name

Function

LCD Display

2 line × 16 character LCD display shows the monitor codes, parameter settings and

operation values of the AC servo drive.

 

 

SON LED (Servo On Indicator). A lit LED illuminates to indicate that the servo drive is

 

enabled.

 

ALRM LED (Alarm Output Indicator). A lit ALRM LED illuminates to indicates that a

 

alarm output is activated.

Status Display

JOG LED (JOG Operation Indicator). A lit JOG LED illuminates to indicates that JOG

(LED Indication)

operation is enabled.

 

TSPD LED (Speed reached Indicator). A lit TSPD LED illuminates to indicates that the

 

target speed is reached and TSPD signal is activated.

 

TPOS LED (Positioning completed Indicator). A lit TPOS LED illuminates to indicates

 

that the target position is reached and TPOS signal is activated.

 

MODE Key. Pressing MODE key can enter or exit different parameter groups, and

MODE

switch between Parameter mode and Parameter Setting mode, SAVE mode and

 

WRITE mode.

 

SHIFT Key. In Parameter mode, pressing SHIFT key can scrolls through parameter

SHIFT

groups. In Parameter Setting mode and SAVE mode, after a parameter is selected and

its value displayed, pressing SHIFT key can move the cursor to the left and then

 

 

change parameter settings (blinking digits) by using arrow keys.

 

 

 

UP and DOWN arrow Key. Pressing the UP and DOWN arrow key can scroll through

 

and change monitor codes, parameter groups and various parameter settings.

 

In SAVE and WRITE mode, pressing UP and DOWN arrow key can scroll through and

 

change the memory blocks. In SAVE mode, pressing UP and DOWN arrow key can

 

select and change the memory file name also.

 

SET Key. Pressing Set key can enter into the Parameter Setting mode, then display,

SET

select and save parameter groups and various parameter settings. During diagnosis

operation, pressing SET key can execute the function in the last step.

 

 

(The parameter settings changes are not effective until the SET key is pressed.)

 

JOG Key. Pressing JOG key can enable JOG operation immediately. 1st pressing:

JOG

enter JOG operation. 2nd pressing: exit JOG operation. Please refer to Section 4.4.3

 

for operation.

ARST

Reset Key. Pressing ARST key can Used to clear a fault (Alarm).

This key is available in any modes.

 

 

 

SAVE

SAVE Key. Pressing SAVE key can save parameter settings to the digital keypad.

Please refer to Section 4.2.2 for operation.

 

 

 

WRITE

WRITE Key. Pressing WRITE key can write out the parameter settings in the digital

keypad and send to the servo drive. Please refer to Section 4.2.3 for operation.

 

 

 

 

Fast Edit Key. Pressing Fast Edit key can use three special functions:

 

Fast Editing, Static Auto-tuning and Dynamic Auto-tuning.

 

Fast editing function:

 

1) 1st pressing: Enable the Fast Editing function. When Fast Editing function is

Fast Edit

enabled, using UP and DOWN arrow key can browse, search and edit the

parameters that have been edited before directly and quickly. The parameter

 

 

setting method is the same as usual.

 

2) 2nd pressing: Disable the Fast Editing function.

 

Static Auto-tuning and Dynamic Auto-tuning function: Please refer to Section 4.2.4

 

for operation.

NOTE

1)The functions of MODE, SHIFT, UP and DOWN, and SET keys are the same as the function keys of ASDA-A series servo drive.

4-2

Revision January 2009

Page 57
Image 57
Delta Electronics ASDA-B Series manual Name Function