Chapter 4 Display and OperationASDA-B Series

4.1.6 DO Force Output Diagnosis Operation

For testing, the digital outputs can be forced to be activated (ON) or inactivated (OFF) by using parameter P4-06. Follow the setting method in Figure 4.10 to enter into DO force output diagnosis operation (OP x) mode (“x” indicates the parameter range from 0 to 7). Pressing UP or DOWN arrow key can change “x” value from 0 to 7 (hexadecimal format) and force digital outputs DO1 to DO3 to be activated (ON) or inactivated (OFF). The DO function and status is determined by P2-18 to P2-20. This function is enabled only when Servo Off (the servo drive is disabled).

Figure 4.10

P 4 - 0 6 : F O T

0

SET

Force DO1 to be activated

Force DO2 to be activated

Force DO3 to be activated

P 4 - 0 6 : F O T

O P

0

P 4 - 0 6 : F O T

O P

1

P 4 - 0 6 : F O T

O P

2

4-14