Chapter 7 Servo ParametersASDA-B Series

 

P1 - 44▲

 

GR1

Electronic Gear Ratio (1st Numerator) (N1)

Communication Addr.: 012CH

 

 

 

 

 

 

 

 

 

Default: 1

 

Related Section:

 

 

 

Applicable Control Mode: P

Section 6.2.4, P1-15, P1-45

 

 

 

Unit: pulse

DI GNUM0(11) in Table 7.A

 

 

 

Range: 1 ~ 32767

 

 

 

 

Settings:

 

 

The electronic gear numerator value can be set via external DI signal (refer to Table 7.A).

DI Name

DI Status

Selected Electronic Gear

 

Not select (Note 1)

P1-44, P1-45

GNUM0

0

P1-44, P1-45

 

1

P1-44, P1-45

NOTE

1)DI signal can be selected by parameter P2-10 to P2-15 and Table 7.A. If uses only need to use one group of electronic gear, it allows users not to select GNUM0.

P1 - 45▲

GR2

Electronic Gear Ratio (Denominator)

Communication Addr.: 012DH

 

 

 

Default: 1

 

Related Section:

Applicable Control Mode: P

Section 6.2.4, P1-15, P1-44

Unit: pulse

DI GNUM0(11) in Table 7.A

Range: 1 ~ 32767

 

Settings:

 

 

Please set electronic gear ratio when the servo drive is Off (Servo Off). As the wrong setting can cause motor to run chaotically (out of control) and it may lead to personnel injury, therefore, ensure to observe the following rule when setting P1-44, P1-45.

The electronic gear ratio settings:

Pulse input

 

 

 

 

Position

 

f1: Pulse input

f2: Position command

 

 

N

command

 

N: Numerator, the setting value of P1-15 or P1-44

 

 

 

M

 

 

 

 

f1

 

 

 

f2 = f1 x

N

 

 

 

 

 

 

 

 

 

 

 

 

M

 

M: Denominator, the setting value of P1-45

The electronic gear ratio setting range must be within: 1/50<N/M<200.

In terms of the servo drive which the firmware version is V1.018 or above, the electronic gear ratio can be set when the servo drive is On (Servo On).