Chapter 7 Servo ParametersASDA-B Series

2: AutoMode (The ratio of Load Inertia to servo motor inertia is fixed)

The ratio of Load Inertia to servo motor inertia is set by parameter P1-37.

The level of stiffness and responsiveness are adjusted by parameter P2-31.

Control Loop Structure Settings:

0:PDFF Control. PDFF : Pseudo-Derivative Feedback and Feedforward

1:PI Control. PI : Proportional - Integral control

Explanation of Auto-tuning:

1.When switching mode #1 to #2 or #0, the system will save the measured load inertia value automatically and memorized in P1-37 and related gain parameters.

2.In AutoMode #1, the system will save the measured load inertia value every 30 minutes automatically and memorized in P1-37.

3.In AutoMode #2, if the setting value of P2-31 changes, the related gain parameters will also change. However, the setting value of P1-37 will retain its value.

4.When switching mode #2 to #0, it indicates the setting of P1-37 and all settings of related gain parameters will be returned to original setting value in #0 manual mode.

5.No matter in Manual mode #0 or in AutoMode #2, the users should enter the appropriate load inertia value in P1-37.

6.If the users use the servo dynamic auto-tuning function of ASDA-B software (Tools Æ Servo Tuning Æ Dynamic Auto tuning), it will save the measured load inertia value and memorized in P1-37 and related gain parameters.

P2 - 33

P2 - 34

Reserved

 

Communication Addr.: 0221H

 

 

 

 

 

 

SDEV

Overspeed Warning Condition

Communication Addr.: 0222H

 

 

 

Default: 5000

Related Section:

Applicable Control Mode: S

Fault Code 07 in P0-01

Unit: rpm

 

 

Range: 1 ~ 6000

Settings:

This parameter is used to set the over speed condition of the drive fault code. (See P0-01)

P2 - 35

PDEV

Excessive Error Warning Condition

Communication Addr.: 0223H

 

 

 

Default: 3000

Related Section:

Applicable Control Mode: P

Fault Code 09 in P0-01

Unit: 10 pulse (10pls)

 

Range: 1 ~ 30000

Settings:

This parameter is used to set the excessive error condition of the drive fault code. (See P0-01)

7-50