Delta Electronics ASDA-B Series manual Wiring Notes

Models: ASDA-B Series

1 321
Download 321 pages 45.58 Kb
Page 28
Image 28

Chapter 3 Connections and WiringASDA-B Series

Wiring Notes

Please observe the following wiring notes while performing wiring and touching any electrical connections on the servo drive or servo motor.

1.Ensure to check if the power supply and wiring of the "power" terminals (R, S, T, U, V, & W) is correct.

2.Please use shielded twisted-pair cables for wiring to prevent voltage coupling and eliminate electrical noise and interference.

3.As a residual hazardous voltage may remain inside the drive, please do not immediately touch any of the "power" terminals (R, S, T, U, V, & W) and/or the cables connected to them after the power has been turned off and the charge LED is lit. (Please refer to the Safety Precautions on page iii).

4.The cables connected to R, S, T and U, V, W terminals should be placed in separate conduits from the encoder or other signal cables. Separate them by at least 30cm (11.8inches).

5.If the encoder cable is too short, please use a twisted-shield signal wire with grounding conductor. The wire length should be 20m (65.62ft.) or less. For lengths greater than 20m (65.62ft.), the wire gauge should be doubled in order to lessen any signal attenuation.

6.As for motor cable selection, please use the 600V PTFE wire and the wire length should be less than 30m (98.4ft.). If the wiring distance is longer than 30m (98.4ft.), please choose the adequate wire size according to the voltage.

7.The shield of shielded twisted-pair cables should be connected to the SHIELD end (terminal marked ) of the servo drive.

8.For the connectors and cables specifications, please refer to section 3.1.6 for details.

9.In this manual, actual measured values are in metric units. The recommended wire lengths in (imperial units) are for reference only. Please use metric for precise measurements.

Revision January 2009

3-3

Page 28