Chapter 6 Control Modes of OperationASDA-B Series

6.2.3 Pulse Inhibit Input Function (INHP)

INHP is activated via digital inputs (Please refer to parameter P2-10 ~ P2-15 and DI INHP(07) in Table 7.A).When the drive is in position mode, if INHP is activated, the external pulse input command is not valid and the motor will stop.

INHP

ON

OFF

ON

Pulse

command

6.2.4 Electronic Gear Ratio

Relevant parameters:

P1 - 15▲

GR4

Electronic Gear Ratio (2nd Numerator) (N2)

Communication Addr.: 010FH

Default: 1

Related Section:

Applicable Control Mode: P

Section 6.2.4, P1-44, P1-45

Unit: pulse

DI GNUM0(11) in Table 7.A

Range: 1 ~ 32767

 

Settings:

 

The electronic gear numerator value can be set via external DI signal (refer to Table 7.A).

DI Name

DI Status

Selected Electronic Gear

 

Not select (Note 1)

P1-44, P1-45

GNUM0

0

P1-44, P1-45

 

1

P1-44, P1-45

NOTE

1)DI signal can be selected by parameter P2-10 to P2-15 and Table 7.A. If uses only need to use one group of electronic gear, it allows users not to select GNUM0.

P1 - 44▲

GR1

Electronic Gear Ratio (1st Numerator) (N1)

Communication Addr.: 012CH

 

 

 

Default: 1

 

Related Section:

Applicable Control Mode: P

Section 6.2.4, P1-15, P1-45

Unit: pulse

DI GNUM0(11) in Table 7.A

Range: 1 ~ 32767

 

Settings:

 

 

The electronic gear numerator value can be set via external DI signal (refer to Table 7.A).