Delta Electronics ASDA-B Series Kptl, Kcmm, Communication Selection Keypad Communication Addr H

Models: ASDA-B Series

1 321
Download 321 pages 45.58 Kb
Page 223
Image 223

Chapter 7 Servo ParametersASDA-B Series

4:Baud rate 57600 (data transmission speed: bits / second)

5:Baud rate 115200 (data transmission speed: bits / second)

P8 - 07

KPTL

Communication Protocol (Keypad)

Communication Addr.: 0807H

 

 

 

Default: 0

 

Related Section: N/A

Applicable Control Mode: P/S/T

Unit: N/A

Range: 0 ~ 8

Settings:

0:Modbus ASCII mode, <7,N,2>

1:Modbus ASCII mode, <7,E,1 >

2:Modbus ASCII mode, <7,O,1>

3:Modbus ASCII mode, <8,N,2 >

4:Modbus ASCII mode, <8,E,1>

5:Modbus ASCII mode, <8,O,1>

6:Modbus RTU mode, <8,N,2>

7:Modbus RTU mode, <8,E,1>

8:Modbus RTU mode, <8,O,1>

P8 - 08

KCMM

Communication Selection (Keypad)

Communication Addr.: 0808H

 

 

 

Default: 0

Related Section: N/A

Applicable Control Mode: P/S/T

 

Unit: N/A

 

Range: 0 ~ 1

 

Settings:

 

0: RS-232

 

1: RS-485

 

Multiple communication modes RS-232, RS-485 cannot be used within one communication ring.

P8 - 09

KTST

Keypad Hardware Testing

Communication Addr.: 0809H

 

 

 

Default: 0

 

Related Section: N/A

Applicable Control Mode: P/S/T

Unit: N/A

Range: 0 ~ 4

Settings:

0:Disabled.

1:Function key testing. Pressing MODE key can exit this testing mode.

7-70

Revision January, 2009

Page 223
Image 223
Delta Electronics ASDA-B Series manual Kptl, Kcmm, Communication Selection Keypad Communication Addr H, Ktst