Delta Electronics ASDA-B Series manual Status Display Save Setting Display

Models: ASDA-B Series

1 321
Download 321 pages 45.58 Kb
Page 83
Image 83

Chapter 4 Display and OperationASDA-B Series

4.2.3Status Display Save Setting Display

After the SET key is pressed, LED display will show the following display messages for approx. one second according to different status.

Display Message

Description

 

 

The setting value is saved correctly.

 

 

 

 

This parameter is read only. Write-protected. (cannot be changed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Invalid password or no password was input.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The setting value is error or input reserve setting value.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The servo module is enabled and this parameter cannot be

 

 

 

 

 

 

 

 

changed.

 

 

 

 

 

 

 

 

 

 

Abort Setting Display

 

 

 

 

 

 

 

 

 

Display Message

 

Description

 

 

 

 

In parameter mode, pressing MODE key can abort parameter

 

 

 

 

setting change and return to monitor mode. In parameter setting

 

 

 

 

mode, pressing MODE key can return back to parameter mode.

 

 

 

 

After returning back to parameter mode, pressing MODE key

 

 

 

 

again can abort parameter setting change.

Fault Message Display

 

 

 

 

 

 

 

 

 

Display Message

 

Description

 

 

 

 

When the AC servo drive has a fault, LED display will display

 

 

 

 

“ALEnn”. “ALE” indicates the alarm and “nn” indicates the drive

 

 

 

 

fault code. The display range of alarm code “nn” is 1 to 48. For the

 

 

 

 

list of drive fault code, please refer to parameter P0-01 or refer to

 

 

 

 

Chapter 10 (Troubleshooting).

Polarity Setting Display

 

 

 

 

 

 

 

 

 

Display Message

 

Description

 

 

 

 

Positive value display. When entering into parameter setting

 

 

 

 

 

 

 

 

mode, pressing UP or DOWN arrow key can increase or decrease

 

 

 

 

the display value. SHIFT key is used to change the selected digit

 

 

 

 

(The selected digit will blink).

 

 

 

 

 

 

 

 

Negative value display. When the parameter setting is greater

 

 

 

 

 

 

 

 

than five digits, after the display value is set, continuously press

 

 

 

 

SHIFT key for six times and then the negative sign will show up to

 

 

 

 

indicate a negative value.

 

 

 

 

4-28

Revision January 2009

Page 83
Image 83
Delta Electronics ASDA-B Series manual Status Display Save Setting Display