Drop and Insert Commands
2-82 Configuring T1/E1 and T3/E3 Subsystems
Applique type is Fractional T1.
Loopback is set as none.
Cablelength long and short 0.
Framing is esf, Line Encoding is b8zs, Clock Source is line.
Description: None
Alarms Detected: None
Rx 0signal level -0.0DB (Accuracy:+/-3DB)
Bypass time slots table ( * data time slots on s/c/0 and s/c/1):
1 1 1 1 1 1 1 1 1 1 2 2 2 2 2
1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4
Rx ABCD * * * * * * F F 0 * F F F F F F F F F F F F F F
Channel 0:
Timeslots 10
64kbps Base rate
Data in current interval (300 seconds elapsed):
0 Line Code Violations
0 Path Code Violations
8 Slip Seconds
0 Frame Loss Seconds
0 Line Error Seconds
0 Degraded Minutes
0 Errored Seconds
0 Bursty Error Seconds
0 Severely Error Seconds
9 Unavailable Seconds
Total Data (Last 0 hours and 0 minutes):
0 Line Code Violations
0 Path Code Violations
0 Slip Seconds
0 Frame Loss Seconds
0 Line Error Seconds
0 Degraded Minutes
0 Errored Seconds
0 Bursty Error Seconds
0 Severely Error Seconds
0 Unavailable Seconds