III PERIPHERAL BLOCK: SERIAL INTERFACE

Control and Operation of IrDA Interface

The transmit/receive procedures have been explained in the section on the asynchronous interface, so refer to "Control and Operation of Asynchronous Transfer".

The following describes the data modulation and demodulation performed using the PPM modulator circuit:

When transmitting

During data transmission, the pulse width of the serial interface output signal is set to 3/16 before the signal is output from the SOUTx pin.

TCLK

1

2

3

8

9

10 11

16

PPM modulator input (I/F output)

16TCLK

PPM modulator output (SOUTx)

3TCLK

Figure 8.16 Data Modulation by PPM Circuit

When receiving

During data reception, the pulse width of the input signal from SINx is set to 16/3 before the signal is transferred to the serial interface.

TCLK

1

2

3

4

16

PPM modulator input (SINx)

3TCLK

PPM modulator output (I/F input)

16TCLK

Figure 8.17 Demodulation by PPM Circuit

Note: When using the IrDA interface, set the internal division ratio of the serial interface 1/16 (DIVMDx = "1"), rather than 1/8 (DIVMDx = "0").

S1C33210 FUNCTION PART

EPSON

B-III-8-23