Analog Input/Output Modules

Labeling of switches on the module cover:

voltage/current

with

8 channels

channel 4±7

 

 

 

16 channels

channel 8±15

broken wire

 

 

8channels

channel0±3

detection

 

 

 

16channels

channel0±7

two's complement

8 channels/resistance thermom.; mV/mA

line frequency 50 CPS

single scanning

1)

 

 

 

 

 

 

 

 

 

 

 

 

 

cyclics canning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

line frequency 60 CPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16 channels mV; mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

result and sign

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with out

8 channels

channel 0±3

 

 

 

 

 

 

 

16 channels

channel 0±7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

broken wire

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

detection

8 channels

channel 4±7

 

 

 

 

 

 

 

16 channels

channel 8±15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

resistance thermometer *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* consider instruction manual

 

 

 

 

 

 

 

resistance thermometer

16 channels ...mV/ ...mA

50 mV

without compensation

I.1)

with compensation

500 mV/ ...mA/ resistance thermometer

8 channels ...mV/ ...mA/ resist. therm.

voltage/current

II.

1)It is advisable to mark the selected switch setting in these fields.

Inserting Range On one 465 analog input module, you can insert four cards for the connection

Cardsof four inputs each, and secure them with a screw. There are voltage divider, shunt and through-connection cards for the various ranges.

 

 

 

 

 

Range Card Type 6ES5 498±

 

 

 

 

 

-1AA11

-1AA21

-1AA31

-1AA41

-1AA51

-1AA61

-1AA71

 

M+

M+

M+

M+

M+

M+

M+

Circuit of the

 

 

 

 

 

 

 

L+

 

 

 

cards 4x

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode

 

"

500 mV

"

"

10 V

"

20 mA

4...20mA

"

5 V

4...20mA

500 mV/ mA

 

1 V

 

 

 

Pt 100

 

 

 

 

 

2-wire trans.

 

 

4-wire trans.

Pt 100

 

 

 

 

 

 

 

 

 

 

 

Mode 50 mV " 50 mV (" 100 mV) (" 1 V) (" 2 mA)

±

(" 500 mV) ±

For a defined mode (50 mV or 500 mV), you can insert cards with different ranges for every four inputs, e.g. for the 500 mV mode:

S4 inputs, range $ 500 mV; 1 card 6ES5 498-1AA11

S8 inputs, range $ 20 mV; 2 cards 6ES5 498-1AA41

Unused inputs must be short-circuited (with Pt 100 operation, this also applies to the unused current outputs).

Note that the bus interface of the module is activated with 24 V via enable lines F+ and F- at the front connector.

System Manual

9-75

C79000-G8576-C199-06

Page 457
Image 457
Siemens S5-135U/155U appendix Mode 50 mV 50 mV 100 mV 1 V 2 mA 500 mV ±