Siemens S5-135U/155U appendix Example of connection designation for an output

Models: S5-135U/155U

1 560
Download 560 pages 1.68 Kb
Page 365
Image 365

Digital Input/Output Modules

Connection of

 

Front Strip

 

 

 

Process Signal

 

 

 

 

 

 

Lines

 

 

 

 

 

 

LED

Pin

 

L+

 

F+

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

3

 

r

 

 

 

1L+

 

+ 1Q0.0

4

 

g

 

 

 

 

 

 

 

 

1L±

 

±1Q0.0

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2L+

 

+ 2Q0.1

6

 

g

 

 

 

 

 

 

 

 

 

 

 

 

 

2L±

 

±2Q0.1

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3L+

 

+ 3Q0.2

8

 

g

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3L±

 

±3Q0.2

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4L+

 

+ 4Q0.3

10

 

g

 

 

 

 

 

 

 

 

 

 

 

 

 

4L±

 

±4Q0.3

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5L+

 

+ 5Q0.4

13

 

g

 

 

 

 

 

 

 

 

5L±

 

±5Q0.4

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6L+

 

+ 6Q0.5

 

g

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6L±

 

±6Q0.5

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7L+

 

+ 7Q0.6

 

g

 

 

 

 

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7L±

 

±7Q0.6

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8L+

 

+ 8Q0.7

 

g

 

 

 

 

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8L±

 

±8Q0.7

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H +

22

 

 

 

 

 

 

 

 

 

H ±

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

9L+

 

+ 9Q1.0

25

 

g

 

 

 

 

 

 

 

 

9L±

 

±9Q1.0

 

 

 

 

 

26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10L+

 

+ 10Q1.1

 

g

 

 

 

 

27

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10L±

 

±10Q1.1

 

 

 

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11L+

 

+ 11Q1.2

 

g

 

 

 

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11L±

 

±11Q1.2

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12L+

 

+ 12Q1.3

 

g

 

 

 

 

31

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12L±

 

±12Q1.3

 

 

 

 

 

32

 

 

 

 

 

 

 

 

 

 

 

Block Diagram of

Module Inputs

t

2)

F1

2)

F5

2)

Short-circuit

2)

F9

Example of connection designation for an output:

x20

(7) Q 0.6

1)

Output 6 (6th bit); 0 to 7 possible

Address of output byte (byte 0);

0 to 255 possible

Q = Output

7th terminal L+ (not specified in the ad- dress)

Data Memory and S5 Bus Control

 

 

 

 

33

 

13L+

 

+ 13Q1.4

g

 

34

 

13L±

±13Q1.4

 

35

 

 

 

 

 

14L+

 

+ 14Q1.5

g

 

36

 

 

14L±

 

±14Q1.5

 

37

 

 

 

 

 

15L+

 

+ 15Q1.6

g

 

38

 

 

15L±

 

±15Q1.6

 

39

 

 

 

 

 

16L+

 

+ 16Q1.7

g

 

40

 

 

16L±

 

±16Q1.7

 

41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42

 

 

 

 

 

 

 

 

 

 

 

2)

F13

2)

Shield

g

=

Green LED (status indicator)

r

= Red LED (short-circuit indicator)

F+/F-

=

Enable input

1)Changeover of enable mode with jumper X20: Jumper inserted = Enable input active (factory setting) Jumper open = Enable input inactive.

2)The terminal is not connected internally. When this terminal is connected to the output voltages, the clearances in air and leakage paths are no longer adequate to UL and CSA, but comply with VDE.

System Manual

8-53

C79000-G8576-C199-06

Page 365
Image 365
Siemens S5-135U/155U appendix Example of connection designation for an output