Central Controllers and Expansion Units Power Supply Units

Replacing the

The lithium battery can be replaced without memory loss if the PSU is

Lithium Battery

switched on, the rechargeable battery is in order or you apply an external

 

(4.5 V) voltage to the ªExt.Batt.º terminals.

How to Replace

Replace the lithium battery in the following steps:

the Lithium Battery

 

Step

Action

1

2

3

4

5

6

7

Slide the battery compartment cover down.

Pull the battery compartment out.

Remove the old lithium battery from the battery compartment by inserting a screwdriver through a hole in the compartment base to push the battery upwards.

Insert the new lithium battery in the battery compartment

Important:

Ensure correct polarity.

Slide the battery compartment in.

Close the cover.

Press the Reset button.

Result (only with PSU on):

±ªMB lowº LED goes off.

±Contacts 14 and 15 of the

Battery Warning relay are bridged.

Replacing a Fan

 

Location of the

The three fans are situated at the bottom of the power supply unit and can be

Fans

individually replaced during operation.

Before

If you operate your power supply with a filter, you must first release the filter

Replacement

subdrawer and pull it out before you can replace a fan (see Section entitled

 

ªReplacing the Filter Matº).

System Manual

4-41

C79000-G8576-C199-06

Page 107
Image 107