Multiprocessor Operation/Coordinators

Step 7

Executing a RESET at all CPUs:

Action

Execute a RESET at each individual CPU:

Hold the MC 1) mode switch at the RESET setting; simultaneously set the mode switch from STOP to RUN.

Reaction

The red STOP LED on each CPU is continuously lit; each CPU emits the output inhibit signal. The CPUs are in the wait state.

 

1) MC: Momentary-contact

Possible Faults

Symptom 1:

 

The STOP LED of one CPU flashes slowly. When the control bits of this

 

CPU are read out with the programmer, ªDB 1 errorº is marked in addition to

 

the usual information. There is no output of an ISTACK.

 

Remedy:

 

Check whether data block DB1 in the CPU was correctly loaded and

 

programmed.

 

Symptom 2:

 

After execution of a RESET:

 

Undefined states or faults occur at the CPUs (e.g. after a RESTART at

 

CPU 922, it goes to the RUN state although the other CPUs are still at

 

STOP).

 

Remedy:

 

Verify the following points:

 

S Is the coordinator inserted?

 

S Are all modules correctly inserted (engaged)?

 

S Are all modules at the correct slots?