Siemens S5-135U/155U appendix Example of connection designation for an input

Models: S5-135U/155U

1 560
Download 560 pages 1.68 Kb
Page 345
Image 345

Digital Input/Output Modules

Connection of

 

Front Strip

Process Signal

 

 

 

Lines

 

 

 

 

 

LED Pin

 

 

F+

 

 

 

 

 

L+

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

L+

 

L+

4)

 

 

3

 

 

 

 

 

1I0.0

 

 

4

g

 

 

 

 

 

1I0.1

 

5

g

 

 

 

 

 

1I0.2

 

6

g

 

 

 

 

 

1I0.3

 

7

g

 

 

 

 

 

1I0.4

 

8

g

 

 

 

 

 

1I0.5

9

g

 

 

 

 

 

1I0.6

 

10

g

 

 

 

 

 

1I0.7

 

11

g

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

1I1.0

 

g

 

 

 

 

 

13

 

 

 

 

 

1I1.1

 

 

 

 

 

 

14

g

 

 

 

 

 

1I1.2

 

 

 

 

 

 

15

g

 

 

 

 

 

1I1.3

 

 

 

 

 

 

16

g

 

 

 

 

 

1I1.4

 

 

 

 

 

 

17

g

 

 

 

 

 

1I1.5

 

 

 

 

 

 

18

g

 

 

 

 

 

1I1.6

 

 

 

 

 

 

19

g

 

 

 

 

 

1I1.7

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

g

 

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

1I2.0

 

g

 

 

 

 

 

25

 

 

 

 

 

1I2.1

 

 

 

 

 

 

26

g

 

 

 

 

 

1I2.2

 

 

 

 

 

 

27

g

 

 

 

 

 

1I2.3

 

 

 

 

 

 

28

g

 

 

 

 

 

1I2.4

 

 

 

 

 

 

29

g

 

 

 

 

 

1I2.5

 

 

 

 

 

 

30

g

 

 

 

 

 

1I2.6

 

 

 

 

 

 

31

g

 

 

 

 

 

1I2.7

 

 

 

 

 

32

g

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

 

 

 

 

 

 

1I3.0

 

g

 

 

 

 

 

34

 

 

 

 

 

1I3.1

 

 

 

 

 

 

35

g

 

 

 

 

 

1I3.2

 

 

 

 

 

 

36

g

 

 

 

 

 

1I3.3

 

 

 

 

 

 

37

g

 

 

 

 

 

1I3.4

 

 

 

 

 

 

38

g

 

 

 

 

 

1I3.5

 

 

 

 

 

 

39

g

 

 

 

 

 

1I3.6

 

 

 

 

 

 

40

g

 

 

 

 

 

1I3.7

 

 

 

 

 

41

g

 

 

 

 

 

 

 

 

 

 

 

3)

 

 

 

 

 

 

42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Block Diagram of Module Inputs

 

t

 

 

t

L+

 

 

 

t

 

2)

t

 

 

 

 

t

 

2)

 

2)

 

 

2)

t

 

 

 

 

t

 

2)

 

 

 

t

 

 

t

Isolation

 

Shield

Example of connection designation for an input:

x20

1) (1) I 3.5

Input 5 (5th bit); 0 to 7 possible

Address of input byte (3rd byte);

0 to 255 possible

I = Input

1st group (not specified in the address)

Data Memory and S5 Bus Control

g

=

Green LED (status indicator)

F+/F-

=

Enable input

1)Changeover of enable mode with jumper X20: Jumper inserted = Enable input active (factory setting) Jumper open = Enable input inactive.

2)The terminal is not connected internally. Even when this terminal is connected to input voltages, the clearances in air and leakage paths remain adequate to UL, CSA and VDE.

3)By connecting L- to pin 42, a leading and trailing connection to ground is established on the module when it is plugged in and removed.

4)L+ to terminal 3 is not required for -4UA14.

System Manual

8-33

C79000-G8576-C199-06

Page 345