Siemens S5-135U/155U appendix Address range, 128 to 255 0 to

Models: S5-135U/155U

1 560
Download 560 pages 1.68 Kb
Page 385
Image 385

Analog Input/Output Modules

9.2Common Technical Specifications

Important for the USA and Canada

The following approvals have been issued:

SUL Listing Mark

Underwriters Laboratories (UL) to Standard UL 508, Report E 85972 and E116536 for the 466-7LA11 analog input module

SCSA Certification Mark

Mark Canadian Standard Association (CSA) to Standard C 22.2 No. 142, Report LR 63533C and LR 48323 for the 466-7LA11 analog input module

Address range

Supply voltage L+ rated value

ripple Vpp

permissible range (including ripple) referencepotential

Voltage for the isolated enable inputs (only required when enable jumper is inserted)

Line lengths for

Analog input modules with rated input range of

$12.5 m, $ 50 mV and Pt 100

Analog input modules with rated input range of $ 500 mV /

$1 / $ 5 / $ 10 V / $ 20 mA, 4 to 20 mA and Pt 100 Analog output modules

Temperature range in operation

for storage ans transportation

Relative humidity

Site altitude

Dimensions (W x H x D)

Weight

128 to 255 (0 to 255)

24V 3.6 V

20to 30 V L±= Mext = 0 V

F+ = + 24 V

F± = 0 V

50 m max. for shielded cables laid separately from power system cables (see Chapter 3)

200 m max., shielded

200 m max., shielded

0 to 55 oC

± 40 to 70 oC

95 % max. at 25 oC, no condensation

3500 m max. above sea level

20 x 255 x 195 mm

Approx. 0.4 kg

System Manual

9-3

C79000-G8576-C199-06