Electrical | ■ | 10 Watts (35 BTU/hour) per 400 module, normal and maximum power consumption |
Specifications | ■ | 65 Watts (225 BTU/hour) per 206 module during normal operation |
| ■ | 100 Watts (350 BTU/hour) per 206 module during maximum power consumption |
|
| |
| ■ 8 Amps maximum current at full system capacity (two carriers with processor module and four | |
|
| 206 modules each) |
|
| On a PARTNER II 220V System: 4.4 Amps maximum current |
| ■ | |
|
|
|
Primary | ■ | 68000 microprocessor, 256Kbytes RAM, 512Kbytes ROM |
Processor Module |
|
|
Specifications |
|
|
|
|
|
Expansion | ■ | 8051 microprocessor, 12mHz, 8Kbytes ROM |
Processor Module |
|
|
Specifications |
|
|
|
|
|
Extension Jack | ■ | Ringing voltage: +5VDC, |
Specifications |
| On a PARTNER II 220V System: +5VDC, |
| ■ | 35- to |
| ■ Ringing frequency: 20 Hz | |
|
|
|
PAGE Jack | ■ | Draws current on inner wire pair |
Specifications | ■ Provides contact closure on outer wire pair | |
| ■ | 600 Ohm impedance |
|
|
|
SMDR Output | ■ | 1200 baud |
Format | ■ | No parity |
| ■ | 8 data bits |
| ■ | 2 stop bits |
|
| |
Environmental | ■ Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required) | |
Requirements— | ■ | Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded |
Control Unit |
| electrical outlet not controlled by a switch, using supplied |
| ■ | Mount the Expansion Carrier at least 6" and not more than 24" away from the Primary Carrier |
| ■ Operating temperature 32° to + 104°F (0° to +40°C), not in direct sunlight | |
| ■ | Humidity |
| ■ For proper ventilation and easy replacement of modules, provide at least 6" (15.2cm) clearance | |
|
| at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit. |
| ■ Locate in an area free of excess moisture, corrosive gases, dust, and chemicals | |
|
|
|
Electrical | ■ | |
Requirements |
| On a PARTNER II 220V System: |
| ■ Outlet must not be controlled by an on/off switch | |
| ■ | Grounding to comply with Underwriters Laboratories (UL) 1459: |
A. An insulated grounding conductor that is not smaller in size and equivalent in insulation material and thickness to the grounded and ungrounded branch circuit supply conductors, except that it is green with or without one or more yellow stripes, is to be installed as part of the circuit that supplies the product or system.
B. The grounding conductor mentioned in item A is to be connected to ground at the service equipment.
C. The