Electrical

10 Watts (35 BTU/hour) per 400 module, normal and maximum power consumption

Specifications

65 Watts (225 BTU/hour) per 206 module during normal operation

 

100 Watts (350 BTU/hour) per 206 module during maximum power consumption

 

 

 

8 Amps maximum current at full system capacity (two carriers with processor module and four

 

 

206 modules each)

 

 

On a PARTNER II 220V System: 4.4 Amps maximum current

 

4-day memory backup (96 hours)

 

 

 

Primary

68000 microprocessor, 256Kbytes RAM, 512Kbytes ROM

Processor Module

 

 

Specifications

 

 

 

 

 

Expansion

8051 microprocessor, 12mHz, 8Kbytes ROM

Processor Module

 

 

Specifications

 

 

 

 

 

Extension Jack

Ringing voltage: +5VDC, -140 VDC peak to peak; trapezoidal wave shaping

Specifications

 

On a PARTNER II 220V System: +5VDC, -150 VDC peak to peak

 

35- to 38-Volt talk battery

 

Ringing frequency: 20 Hz

 

 

 

PAGE Jack

Draws current on inner wire pair

Specifications

Provides contact closure on outer wire pair

 

600 Ohm impedance

 

 

 

SMDR Output

1200 baud

Format

No parity

 

8 data bits

 

2 stop bits

 

 

Environmental

Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)

Requirements—

Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded

Control Unit

 

electrical outlet not controlled by a switch, using supplied 7-foot (2.1-meter) cords

 

Mount the Expansion Carrier at least 6" and not more than 24" away from the Primary Carrier

 

Operating temperature 32° to + 104°F (0° to +40°C), not in direct sunlight

 

Humidity 15%–90%, noncondensing

 

For proper ventilation and easy replacement of modules, provide at least 6" (15.2cm) clearance

 

 

at the top and sides and 2 feet (0.6 meters) at the front and bottom of the control unit.

 

Locate in an area free of excess moisture, corrosive gases, dust, and chemicals

 

 

 

Electrical

90–130 VAC, 50–60 Hz, 3-prong outlet separate ground, separately fused at 15 Amps

Requirements

 

On a PARTNER II 220V System: 180–264 VAC, fused at 10 Amps

 

Outlet must not be controlled by an on/off switch

 

Grounding to comply with Underwriters Laboratories (UL) 1459:

A. An insulated grounding conductor that is not smaller in size and equivalent in insulation material and thickness to the grounded and ungrounded branch circuit supply conductors, except that it is green with or without one or more yellow stripes, is to be installed as part of the circuit that supplies the product or system.

B. The grounding conductor mentioned in item A is to be connected to ground at the service equipment.

C. The attachment-plug receptacles in the vicinity of the product or system are all to be of a grounding type, and the grounding conductors serving these receptacles are to be connected to earth ground at the service equipment.

A-2Specifications

Page 260
Image 260
AT&T 518-455-317 manual Electrical