■Error code B0
Scanner Error
Scanning FFC connection malfunction
* This error is indicated on the LCD in the maintenance mode.
Step | Cause | Remedy | |
|
|
| |
1 | Harness for CCD unit not | Reconnect the harness for the CCD unit | |
connected correctly. | correctly. | ||
| |||
|
|
| |
2 | Scanner harness broken | Replace the FFC cable ASSY. | |
|
|
| |
3 | Main PCB failure | Replace the main PCB ASSY. | |
|
|
|
■Error code B1
Scanner Error
Dark level offset data level error for scanning
* This error is indicated on the LCD in the maintenance mode.
Error code B2
Scanner Error
Gain control data level error for scanning
* This error is indicated on the LCD in the maintenance mode.
Error code B7
Scanner Error
A/D converter standard voltage failure; at High side
* This error is indicated on the LCD in the maintenance mode.
Error code B8
Scanner Error
A/D converter standard voltage failure; at Low side
* This error is indicated on the LCD in the maintenance mode.
Step | Cause | Remedy |
|
|
|
|
|
|
1 | CCD unit failure | Replace the CCD unit. |
|
|
|
2 | Main PCB failure | Replace the main PCB ASSY. |
|
|
|
3 | White tape malfunction | Replace the scanner unit. |
|
|
|
Confidential |