(2) Command reception

 

Code 1

Code 2

Causes

 

 

 

 

 

 

 

 

 

20

01

Unable to detect a flag field.

 

 

 

 

 

20

02

Carrier was OFF for 200 ms or longer.

 

 

 

 

 

20

03

Abort detected (“1” in succession for 7 bits or more).

 

 

 

 

 

20

04

Overrun detected.

 

 

 

 

 

20

05

A frame for 3 seconds or more received.

 

 

 

 

 

20

06

CRC error in answerback.

 

 

 

 

 

20

07

Echo command received.

 

 

 

 

 

20

08

Invalid command received.

 

 

 

 

 

20

09

Command ignored once for document setting or for

 

dumping-out at turn-around transmission.

 

 

 

 

 

 

 

 

20

0A

T5 time-out error

 

 

 

 

 

20

0B

CRP received.

 

 

 

 

 

20

0C

EOR and NULL received.

 

 

 

 

(3) Communication code compatibility [checking the NSF and DIS]

 

 

 

 

 

Code 1

Code 2

Causes

 

 

 

 

 

 

 

 

 

32

01

Remote terminal only with V.29 capability in 2400 or

 

4800 bps transmission.

 

 

 

 

 

 

 

 

32

02

Remote terminal not ready for polling.

 

 

 

 

 

 

 

 

 

32

10

Remote terminal not equipped with password function

 

or its password switch OFF.

 

 

 

 

 

 

 

 

32

11

Remote terminal not equipped with or not ready for

 

confidential mailbox function.

 

 

 

 

 

 

 

 

32

12

Remote terminal not equipped with or not ready for relay

 

broadcasting function.

 

 

 

 

 

 

 

 

32

13

No confidential mail in the remote terminal.

 

 

 

 

 

 

 

The available memory space of the remote terminal is

 

32

14

less than that required for reception of the confidential

 

 

 

or relay broad-casting instruction.

 

 

 

 

 

32

18

Remote terminal not equipped with color function.

 

 

 

 

 

 

 

 

3-63

Confidential