Periodical replacement parts are the parts to be replaced periodically to maintain product quality. These parts would affect the product quality greatly if they lost their function even if they do not appear to be damaged or there is no change in their appearance.
The periodical replacement parts listed below should be replaced at the service center referring to the service life.
Parts Name | LCD Message | Qty | Approximate Life *1 | Replacement | |
(number of prints) | Procedure | ||||
|
| ||||
Fuser Unit | REPLACE FUSER | 1 | 100,000 pages | See subscription | |
|
|
|
| ||
Laser Unit | REPLACE LASER | 1 | 100,000 pages | ||
| |||||
|
|
|
|
| |
PF kit for Tray 1 *3 | REPLACE PF KIT1 | 1 | 100,000 pages | See subscription | |
|
|
|
| ||
PF kit for Tray 2 *3 | REPLACE PF KIT2 | 1 | 100,000 pages | ||
|
|
| Except for China/ | See subscription | |
|
|
| India: 50,000 pages | ||
MP PF tray *2 | REPLACE PF KIT MP | 1 | China: |
| |
|
|
| 25,000 pages |
| |
|
|
| India: |
| |
|
|
| 12,000 pages |
|
To reset the count of each periodical replacement parts, refer to "5.1 Resetting the Periodical Replacement Parts Life" in Chapter7.
*1 At 5% print coverage (A4 or Letter size). The actual number of printed pages will vary depending on the print jobs and paper you use. The number is calculated when simplex printed the normal business document (ISO/IEC19752) on the A4 size.
*2 Paper feeding kit MP means the MP roller holder ASSY and the separation pad ASSY MP.
*3 Paper feeding kit for Tray 1, Tray 2 and Tray 3 means the roller holder ASSY, the separation pad ASSY and the separation pad spring. Tray 1, Tray 2 and Tray 3 are the same kit.
Note :
•Always turn off the power switch of the printer and unplug the power cord from the power outlet before replacing the periodical replacement parts.
•If the Fuser Unit is replaced after errors related to the Fuser Unit occur, it is necessary to leave the printer power ON for ten minutes after part replacement. This will make the printer to be released from errors.
•After disconnecting flat cables, check that each cable is not damaged at its end or short- circuited.
•When connecting flat cables, do not insert them at an angle. After insertion, check that the cables are not at an angle.