<WSW50>
Selector No. | Function |
| Setting and Specifications | |
|
|
|
| |
| Percentage voltage for | No. 1 | 2 | |
| interpreting the external | |||
1 | 0 | 0: 50 % | ||
telephone as being hooked up | ||||
0 | 1: 80 % | |||
| ||||
2 | (based on the network's | |||
1 | 0: 30 % | |||
standard voltage) | ||||
| ||||
| 1 | 1: No detection | ||
| (Not used.) | |||
|
|
| ||
|
|
|
| |
| DC mask curve table to be | 0: Apply the initial value specified by local | ||
| applied when the line is | |||
3 | regulations | |||
connected | ||||
| 1: Apply table DC5 prepared specially | |||
| (Not used.) | |||
|
|
| ||
|
|
|
| |
| AC impedance to be applied | 0: 600Ω termination | ||
4 | when the line is connected | |||
1: ZR termination | ||||
| (Not used.) | |||
|
|
| ||
|
|
|
| |
|
| No. 5 | 6 | |
| Current control to be applied | 0 | 0: Standard | |
5 | 0 1: Increase | |||
immediately after connection of | ||||
| termination | |||
|
| |||
6 | the line |
| ||
1 0: Fine current control for | ||||
(Not used.) | ||||
| ||||
|
| termination | ||
|
|
| ||
|
| 1 1: Not used. (equal to "0, 0") | ||
|
|
|
| |
|
| No. 7 | 8 | |
7 | AC voltage threshold for | 0 | 0: 19 V | |
detection of ring | 0 | 1: 11 V | ||
8 | ||||
(Not used.) | 1 | 0: 25 V | ||
| ||||
|
| 1 | 1: 31 V | |
|
|
|
|