<WSW04>

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

1

Earth function in transfer facility

0: Provided

1: Not provided

(Not used.)

 

 

 

 

 

 

 

 

 

 

 

 

 

No. 2

3

 

 

2

Dual tone detection frequency in

0

0: 350 and 440 Hz (A)

0

1: 440 and 480 Hz (B)

 

3

ICM recording (Not used.)

1

0: 480 and 620 Hz (C)

 

 

 

 

 

1

1: 480 and 620 Hz (C)

 

 

 

 

 

 

4

Dual tone detection sensitivity in

0: Normal

1: High

ICM recording (Not used.)

 

 

 

 

 

 

 

 

 

 

 

 

Length of time added to time

 

 

 

 

 

designated by selectors 3 and 4

 

 

 

 

5

on the WSW 24 (time between

0: Not added

1: +4 seconds added

 

CML ON and pseudo ring

 

 

 

 

 

backtone return).

 

 

 

 

 

 

 

 

 

 

 

 

No. 6

7

8

 

 

 

0

0

0: 80 ms

6

 

0

0

1: 100 ms

 

0

1

0: 110 ms

 

Break time length for flash

I

0

1

1: 120 ms

function

 

1

0

0: 200 ms

8

 

 

1

0

1: 250 ms

 

 

 

 

1

1

0: 500 ms

 

 

1

1

1: 700 ms

 

 

 

 

 

 

Note:

Selectors 1 and 5 through 8 are not applicable in those countries where no transfer facility is supported.

Selectors 6 and 8: Break time length for flash function

These selectors set the break time length. This setting is effective only when the flash function is selected for the [Search/Speed Dial] button by using the function switch.

App. 1-9