<WSW18>

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

1

Addition of registration of station

 

 

 

ID for PC-FAX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No. 2

3

 

2

Detection enabled time for CNG

0

0: 40 sec.

 

0

1: 0 sec. (No detection)

 

3

and no tone

1

0: 5 sec.

 

 

 

 

 

 

 

 

1

1: 80 sec.

 

 

 

 

 

 

4

Not used.

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

6

Registration of station ID

0: Permitted

1: Prohibited

 

 

 

 

 

 

 

No. 7

8

 

 

 

0

0: No monitoring

7

 

0

1: No monitoring

Tone sound monitoring

1

0: Up to phase B at the calling

8

 

 

station only

 

 

 

 

 

1

1: All transmission phases both

at the calling and called stations

Selector 1: Addition of registration of station ID for PC-FAX

The sending state is as follows whether add the station ID in the PC side or not.

The data do not add the station ID in the PC side.

Follow the Selector 1 in WSW 18, add the station ID or not.

The data add the station ID in the PC side.

Let it lie in the main body side.

Selectors 2 and 3: Detection enabled time for CNG and no tone

After the line is connected via the external telephone or by picking up the handset of the machine, the machine can detect a CNG signal or no tone for the time length specified by these selectors. The setting specified by these selectors becomes effective only when selector 8 on WSW20 is set to "1."

Selector 6: Registration of station ID

Setting this selector to "0" permits the registration of station ID for Austrian and Czech models.

Selectors 7 and 8: Tone sound monitoring

These selectors set monitoring specifications of the tone sound inputted from the line.

App. 1-24

Confidential