<WSW55>
Selector No. | Function | Setting and Specifications | |
|
|
| |
|
| 0: The developing bias voltage | |
|
| correction is performed on each | |
|
| print job. | |
1 | Interval of time required for | ||
I | the developing bias voltage | correction is performed when a | |
correction (hour) | print job occurs at specified | ||
| |||
8 | (Not used.) | time or later. | |
|
| ||
|
| 255 (0xFF): The developing bias voltage | |
|
| correction is not performed. | |
|
|
|
The setting example of the selector number is as follows;
No.1 2 3 4 5 6 7 8
00 0 0 0 0 0 0 : The developing bias voltage correction is performed on each print job.
00 0 1 1 0 0 0 : The developing bias voltage correction is performed when a print job occurs after 24 hours (default value) or later.
00 0 1 0 0 1 0 : The developing bias voltage correction is performed when a print job occurs after 72 hours or later.
11 1 1 1 1 1 1 : The developing bias voltage correction is not performed.
App. | Confidential |