LCD indication

Description

Set value

Initial

value

 

 

 

 

 

 

 

 

 

 

 

AutoFF Time

Switching of the time-out period of

1 to 99 (seconds)

5

 

the auto feed

 

 

 

 

FF Surpress

Switching of the FF Surpress

On/Off

Off

 

 

 

 

- Auto LF

Switching of the auto LF

On/Off

Off

 

 

 

 

- Auto CR

Switching of the auto CR

On/Off

Off

 

 

 

 

- Auto WRAP

Switching of the auto CRLF at the

On/Off

Off

 

print width

 

 

 

 

- Auto SKIP

Switching of the SKIP at the back-

On/Off

On

 

end/tip of the recording paper

 

 

 

 

- Left Margin

Switching of the margin at the left

0 to 145 (columus)

0

 

end

 

 

 

 

- Right Margin

Switching of the margin at the right

10 to 155 (columus)

80

 

end

 

 

 

 

- Top Margin

Switching of the margin at the upper

0 to 2.00 (inches)

0.5

 

end

 

 

 

 

- Bottom Margin

Switching of the margin at the

0 to 2.00 (inches)

0.5

 

bottom end

 

 

 

 

- Lines

Number of the text lines in the page

5 to 128 (lines)

60

 

 

 

 

- Error Print

Switching of the Error Print of the

On/Off

On

 

Post Script

 

 

 

 

Detail description

LCD indication

Detail description

 

 

Manual Feed

Effective for the print from the PC, or for the print of the NetWorkConfig/

 

TestPrint/Fontlist/Configuration from the panel. When select the tray on

 

the PC, the setting becomes effective. And this setting is ignored.

Resolution

Effective only for the print from the PC. When set the Resolution on the

 

PC, the setting becomes effective. And this setting is ignored.

Toner Save

Effective for all print, and change the setting of the Function Menu.

 

However, as for the Copy, this setting becomes invalid. When set the

 

Toner Save or the PC, the setting becomes effective. And this setting is

 

ignored.

Density

Effective for the print from the PC, or for the print of the NetWorkConfig/

 

TestPrint/FontList/Configuration from the panel. Link the setting of the

 

Toner Save. Judge the both setting, and decide the density. When set

 

the Density or the PC, the setting becomes effective. And this setting is

 

ignored.

Job Cancel

Configure the setting for until the host time-out at the Job Cancel.

TimeOut

The setting value is the second time scale.

Sleep Time

Configure the setting for the time until shift to the Sleep Time. Change

 

the setting of the Function Menu.

Pege

Configure the setting to protect the page memory, when recording in PC.

Protection

Set in the PCL-Core. There is not the influence of the memory

 

management problem of the MFC.

Emulation

Configure the setting for the Emulation. Charge the setting of the

 

Function Menu. When the data include the ENTER LANGUAGE, the

 

setting becomes effective. And this setting is ignored.

7-20