<WSW41>

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

 

No. 1

2

3

 

 

 

0

0

0: 16 hours

1

 

0

0

1: 24 hours

 

0

1

0: 12 hours

 

ON-duration of the scanning

I

0

1

1: 8 hours

light source at room temperature

 

1

0

0: 4 hours

3

 

 

1

0

1: 2 hours

 

 

 

 

1

1

0: 1/6 hours

 

 

1

1

1: 0 hours

 

 

 

 

 

4

I-FAX relay report

0: ON

 

1: OFF

 

 

 

 

 

 

 

 

No. 5

6

7

8

 

 

0

0

0

0: -10 dBm

5

 

0

0

0

1: -11 dBm

I

Modem attenuator

0

0

1

0: -12 dBm

0

0

1

1: -13 dBm

 

 

8

 

0

1

0

0: -14 dBm

 

 

 

 

 

 

 

1

1

1

1: -25 dBm

 

 

 

 

 

 

Selectors 1 through 3: ON-duration of the scanning light source at room temperature

If the scanning operation is started when the scanning light source is off, then it will come on for scanning. These selectors determine how long the light source is ON after scanning.

If these selectors are set to "1, 1, 1," the CCD unit goes off for protection of the CCD unit for 10 minutes after the scanning sequence.

Selectors 5 through 8: Modem attenuator

These selectors are used to adjust the transmitting level of the modem when the reception level at the remote station is improper due to line loss. This function applies to super G3 protocol signals.

App. 1-49