<WSW25>

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

 

No. 1

2

 

 

1

External TAD no-tone detection

0

0: 0 sec.

 

0

1: 8 sec.

 

 

 

2

start delay time

 

1

0: 16 sec.

 

 

 

 

 

 

 

 

1

1: 24 sec.

 

 

 

 

 

 

 

 

 

No. 3

4

 

 

3

External TAD no-tone detection

0

0: -43 dB

(A)

0

1: -46 dB

(B)

 

4

level

1

0: -49 dB

(C)

 

 

 

 

 

1

1: -51 dB

(D)

 

 

 

 

 

 

 

 

No. 5

6

7

 

 

 

0

0

0: 2 sec.

5

 

0

0

1: 4 sec.

 

0

1

0: 6 sec.

 

Pause between paging number

I

0

1

1: 8 sec.

and PIN (Not used.)

 

1

0

0: 10 sec.

7

 

 

1

0

1: 12 sec.

 

 

 

 

1

1

0: 14 sec.

 

 

1

1

1: 16 sec.

 

 

 

 

 

 

8

Not used.

 

 

 

 

 

 

 

 

 

 

Note:

Selectors 5 through 7 are applicable to the U.S.A. models only.

Selectors 1 and 2: External TAD no-tone detection start delay time

Valid only for the external TAD mode. This machine will delay the start of detection for no tone by the length of time set by selectors 1 and 2.

The sum of the detection delay time setting and the waiting time for no-tone detection setting by selectors 1 through 5 of WSW21 must be within 40 seconds or less.

Selectors 3 and 4: External TAD no-tone detection level

These selectors set the no-tone detection level in the external TAD mode.

App. 1-31