<WSW57>
Selector No. | Function |
| Setting and Specifications | ||
|
|
|
|
| |
|
| No. 1 | 2 | 3 | |
|
| 0 | 0 | 0: 0 V | |
1 |
| 0 | 0 | 1: 5 V (Default) | |
Caller ID judgment voltage | 0 | 1 | 0: 10 V | ||
| |||||
I | (to be distinguished from rings) | 0 | 1 | 1: 15 V | |
3 | (Not used.) | 1 | 0 | 0: 20 V | |
| 1 | 0 | 1: 25 V | ||
|
| ||||
|
| 1 | 1 | 0: 30 V | |
|
| 1 | 1 | 1: Max. | |
|
|
|
|
| |
|
| No. 4 | 5 | 6 | |
|
| 0 | 0 | 0: 0 V | |
4 | Caller ID judgment voltage | 0 | 0 | 1: 5 V (Default) | |
0 | 1 | 0: 10 V | |||
| (to be distinguished from | ||||
I | 0 | 1 | 1: 15 V | ||
reverse polarity voltages) | |||||
| 1 | 0 | 0: 20 V | ||
6 | (Not used.) | ||||
1 | 0 | 1: 25 V | |||
|
| ||||
|
| 1 | 1 | 0: 30 V | |
|
| 1 | 1 | 1: Max. | |
|
|
|
|
| |
7 | Not used. |
|
|
| |
|
|
|
|
| |
| Base unit [Start] button after |
|
|
| |
8 | cordless handset dialing | 0: Invalid (Default) 1: Valid | |||
| (Not used.) |
|
|
| |
|
|
|
|
|
App. | Confidential |