<WSW08>

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

No. 1

2

3

 

 

0

0

0: 50 ms

1

 

0

0

1: 250 ms

 

0

1

0: 500 ms

 

1st dial tone detection time

I

0

1

1: 620 ms

length

 

1

0

0: 800 ms

3

 

 

1

0

1: 1.5 sec.

 

 

 

 

1

1

0: 2.0 sec.

 

 

1

1

1: 2.5 sec.

 

 

 

 

 

 

 

No. 4

5

 

4

Time-out length for 1st and 2nd

0

0: 10 sec.

0

1: 20 sec.

 

5

dial tone detection

1

0: 15 sec.

 

 

 

 

 

1

1: 30 sec.

 

 

 

 

 

 

 

No. 6

7

8

 

 

0

0

0: -21 dBm

6

 

0

0

1: -24 dBm

 

0

1

0: -27 dBm

 

Detection level of 1st dial tone

I

0

1

1: -30 dBm

and busy tone before dialing

 

1

0

0: -33 dBm

8

 

 

1

0

1: -36 dBm

 

 

 

 

1

1

0: -39 dBm

 

 

1

1

1: -42 dBm

 

 

 

 

 

Note:

The WSW08 is not applicable in those countries where no dial tone detection is supported, e.g., U.S.A.

Selectors 1 through 3: 1st dial tone detection time length

Upon detection of the 1st dial tone for the time length set by these selectors, the machine starts dialing. This setting is effective only when selectors 1 through 3 on WSW05 are set to "1,1,1."

Selectors 4 and 5: Time-out length for 1st and 2nd dial tone detection

These selectors set the time-out length for the 1st and 2nd dial tone detection so that the machine waits dial tone input for the specified time length and disconnects itself from the line when no dial tone is inputted.