9.64Main PCB

(1)Disconnect the 6 connectors and 6 flat cables from the Main PCB.

Caution:

After disconnecting flat cable(s), check that each cable is not damaged at its end or short-circuited.

When connecting flat cable(s), do not insert them at an angle. After insertion, check that the cables are not at an angle.

DX solenoid connector (For the models

with the DX only)

Relay rear (Flat cable) Relay front (Flat cable)

LD harness (Flat cable)

Wireless PCB harness (For the model with the Wireless LAN only)

Polygon motor (Flat cable)

LVPS PCB connector

Main motor (Flat cable)

Ferrite core

Thermistor connector

HVPS PCB (Flat cable)

FAN connector LT connector

Fig. 5-131

Assembling Note:

• When assembling the Main PCB, ensure to place the Ferrite Core correctly.