<WSW11>

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

No. 1

2

1

Busy tone frequency band

0 0: Narrows by 10 Hz

0

1: Initial value

 

2

control

1 0: Widens by 10 Hz

 

 

 

 

 

1 1: Widens by 10 Hz

 

 

 

3

 

1: 250-750/250-750 ms

 

 

 

4

 

1: 400-600/400-600 ms

 

ON/OFF time length ranges for

 

 

5

1: 175-440/175-440 ms

busy tone (More than one

 

 

 

6

1: 100-1000/17-660 ms

setting allowed)

 

 

 

7

 

1: 110-410/320-550 ms

 

 

 

8

 

1: 100-660/100-660 ms

 

 

 

 

Note:

WSW11 is not applicable in those countries where no busy tone detection is supported.

The setting of WSW11 is effective only when selectors 5 and 6 on WSW05 are set to "0, 1" or "1, 1" (Busy tone detection).

Selectors 1 and 2: Busy tone frequency band control

These selectors set the frequency band for busy tone to be detected.

Selectors 3 through 8: ON/OFF time length ranges for busy tone

These selectors set the ON and OFF time length ranges for busy tone to be detected. If more than one selector is set to "1," the ranges become wider. For example, if selectors 4 and 5 are set to "1," the ON and OFF time length ranges are from 175 to 600 ms.