Error code 6A

Print Unable 6A

Turn the power off and then back on again.

Fuser temperature does not detect 60°C within the specified time (center thermistor)

Error code 6B

Print Unable 6B

Turn the power off and then back on again.

Fuser temperature does not detect 100°C within the specified time (center thermistor)

Error code 6C

Print Unable 6C

Turn the power off and then back on again.

Detect higher temperature error (center thermistor)

Error code 6D

Print Unable 6D

Turn the power off and then back on again.

Detect lower temperature error (center thermistor)

Error code 6E

Print Unable 6E

Turn the power off and then back on again.

Detect non temperature rising error (center thermistor)

Error code 6F

Print Unable 6F

Turn the power off and then back on again.

Hardware detects extremely high temperature of the center or side thermistors

Step

Cause

Remedy

 

 

 

1

Fuser unit failure

Replace the fuser unit.

 

 

 

2

Main PCB failure

Replace the main PCB ASSY.

 

 

 

3-19

Confidential