9.88MP Unit(1)Cut the Binder bundling the harnesses with nippers.
Binder
Paper feed frame
Cut
PE EG sensor connector
MP PE sensor connector
Fig. 5-186
(2)Remove the two bind B M3x8 Taptite screws.
(3)Lift up the back side of the MP feed frame and pull up the MP feed frame to remove.
Taptite, bind B M3x8
MP feed frame
Taptite, bind B M3x8
Hook
3b
3a
Paper feed frame
Hook
Fig. 5-187