<WSW62>
Selector No. | Function |
|
| Setting and Specifications | ||||
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Change rate | Change rate | |
|
| No. 1 | 2 | 3 | 4 | for simple | for regular | |
|
|
|
|
|
| compensation | compensation | |
|
| 0 | 0 | 0 | 0: | 3% | 10% * | |
|
| 0 | 0 | 0 | 1: | 3% | 7% | |
|
| 0 | 0 | 1 | 0: | 3% | 15% | |
|
| 0 | 0 | 1 | 1: | 3% | 20% | |
|
| 0 | 1 | 0 | 0: | 3% | 25% | |
1 | Change rate of the CCD | 0 | 1 | 0 | 1: | 5% | 10% | |
| 0 | 1 | 1 | 0: | 5% | 15% | ||
I | light intensity for scanning | |||||||
0 | 1 | 1 | 1: | 5% | 20% | |||
| pages compensation | |||||||
4 | 1 | 0 | 0 | 0: | 5% | 25% | ||
| ||||||||
|
| 1 | 0 | 0 | 1: | 7% | 15% | |
|
| 1 | 0 | 1 | 0: | 7% | 20% | |
|
| 1 | 0 | 1 | 1: | 7% | 25% | |
|
| 1 | 1 | 0 | 0: | 10% | 15% | |
|
| 1 | 1 | 0 | 1: | 10% | 20% | |
|
| 1 | 1 | 1 | 0: | 10% | 25% | |
|
| 1 | 1 | 1 | 1: | 15% | 30% | |
|
|
|
|
|
|
| * Default | |
|
|
|
|
|
|
|
| |
5 | Selection of judging function | No. 5 | 6 |
|
|
|
| |
0 | 0: Judges according to the change rate | |||||||
for simple scanning pages | ||||||||
6 | 0 | 1: Not judges |
| |||||
compensation |
| |||||||
| 1 | 0: Judges every page |
| |||||
|
|
| ||||||
7 | Selection of judging function | No. 7 | 8 |
|
|
|
| |
0 | 0: Judges according to the change rate | |||||||
for regular scanning pages | ||||||||
8 | 0 | 1: Not judges |
| |||||
compensation |
| |||||||
| 1 | 0: Judges every page |
| |||||
|
|
| ||||||
|
|
|
|
|
|
|
|
•Selectors 1 through 4:Change rate of the CCD light intensity for scanning pages compensation
The light intensity of the CCD unit may be changed (decreased, especially), and difference of density may appear among the scanning pages if continuous copying or scanning is implemented from the ADF for a long time. To prevent the above, in simplex copying or scanning from the ADF, the machine checks the change rate of the light intensity in every page. Then, it takes the compensation data again if the rate is over the set value. These selectors set the change rate of the light intensity to control such operations.
Change rate for simple compensation:
Change rate when compensating the pages using the standard data in the machine memory without moving the CCD unit to the designated position for scanning of the compensation data.
Change rate for regular compensation:
Change rate when compensating the pages with moving the CCD unit to the designated position for scanning of the compensation data and obtaining the data actually.
For duplex scanning, this setting is not used since the machine takes the compensation data of every page again.
App. | Confidential |