(8)Remove the pan B M4x20 Taptite screw. Release the Hooks in the order of 8a, 8b and 8c. Remove the FU harness cover 1.

8c

8a

8b

Taptite pan B M4x20

Hooks

FU harness cover 1

 

Fig. 4-4

(9)Disconnect the connector of the Heater terminal while pressing the Hook of the connector of the Fuser unit.

Fuser unit

Hook

Heater terminal

Frame R

Fig. 4-5