■Error code D1
Machine Error D1
Modem initialization failed
Step | Cause | Remedy |
|
|
|
|
|
|
1 | Main PCB failure | Replace the main PCB ASSY. |
|
|
|
■Error code DD
Fusser Error
Turn the power off, then on again. Leave the machine for 15min.
Fuser error other than 58, 59, 68, 69, 6A, 6B, 6C, 6D, 6E, 6F, 76, 78, DE and E2 are occurred.
Step | Cause | Remedy |
|
|
|
|
|
|
1 | Fuser unit failure | Replace the fuser unit. |
|
|
|
2 | Main PCB failure | Replace the main PCB ASSY. |
|
|
|
3 | LVPS PCB failure | Replace the LVPS PCB ASSY. |
|
|
|
■Error code DE
Fusser Error
Turn the power off, then on again. Leave the machine for 15min.
Central temperature of heat roller detected the temperature that was lower than edge (60°C)
Step | Cause | Remedy | |
|
|
| |
1 | Relay rear PCB ASSY connection | Reconnect the relay rear PCB ASSY | |
failure | connector correctly. | ||
| |||
|
|
| |
2 | Main PCB failure | Replace the main PCB ASSY. | |
|
|
|
■Error code E0
Print Unable E0
Turn the power off and then back on again.
Program error
Step | Cause | Remedy |
|
|
|
|
|
|
1 | Program failure | Reinstall the latest firmware. |
|
|
|
2 | Main PCB failure | Replace the main PCB ASSY. |
|
|
|