Error code D1

Machine Error D1

Modem initialization failed

Step

Cause

Remedy

 

 

 

 

 

 

1

Main PCB failure

Replace the main PCB ASSY.

 

 

 

Error code DD

Fusser Error

Turn the power off, then on again. Leave the machine for 15min.

Fuser error other than 58, 59, 68, 69, 6A, 6B, 6C, 6D, 6E, 6F, 76, 78, DE and E2 are occurred.

Step

Cause

Remedy

 

 

 

 

 

 

1

Fuser unit failure

Replace the fuser unit.

 

 

 

2

Main PCB failure

Replace the main PCB ASSY.

 

 

 

3

LVPS PCB failure

Replace the LVPS PCB ASSY.

 

 

 

Error code DE

Fusser Error

Turn the power off, then on again. Leave the machine for 15min.

Central temperature of heat roller detected the temperature that was lower than edge (60°C)

Step

Cause

Remedy

 

 

 

1

Relay rear PCB ASSY connection

Reconnect the relay rear PCB ASSY

failure

connector correctly.

 

 

 

 

2

Main PCB failure

Replace the main PCB ASSY.

 

 

 

Error code E0

Print Unable E0

Turn the power off and then back on again.

Program error

Step

Cause

Remedy

 

 

 

 

 

 

1

Program failure

Reinstall the latest firmware.

 

 

 

2

Main PCB failure

Replace the main PCB ASSY.

 

 

 

3-36