<WSW12>

Selector No.

Function

 

Setting and Specifications

 

 

 

 

 

 

 

No. 1

2

 

1

Min. detection period required

0

0: 1500 ms

 

for interpreting incoming calling

0

1: 500 ms

 

2

 

signal (CI) as OFF

1

0: 700 ms

 

 

 

 

 

1

1: 900 ms

 

 

 

 

 

 

 

 

No. 3

4

 

3

Max. detection period for

0

0: 6 sec.

 

incoming calling signal (CI)

0

1: 7 sec.

 

4

 

being OFF

1

0: 9 sec.

 

 

 

 

 

1

1: 11 sec.

 

 

 

 

 

 

 

 

No. 5

6

 

5

Min. detection period required

0

0: 800 ms (1000 ms*)

for acknowledging incoming

0

1: 200 ms

 

6

 

calling signal (CI) as ON

1

0: 250 ms

 

 

 

 

 

1

1: 150 ms

 

 

 

 

 

7

Line connection timing

0: Ringer-OFF

1: Ringer-ON

 

period

period

 

 

 

 

 

 

 

 

8

Not used.

 

 

 

 

 

 

 

 

* 1000 ms in Chinese models.

Selectors 1 through 4:Min. detection period required for interpreting incoming calling signal (CI) as OFF

Max. detection period for incoming calling signal (CI) being

OFF

If the machine detects the OFF state of a CI signal for the period greater than the value set by selectors 1 and 2 and less than the value set by selectors 3 and 4, it interprets the CI signal as OFF.

Selectors 5 and 6: Min. detection period required for acknowledging incoming calling signal (CI) as ON

These selectors set the period required to make the machine acknowledge itself to be called. That is, if the machine continuously detects a CI signal with the frequency set by selectors 1 through 4 on WSW14 during the period set by these selectors 5 and 6, then it acknowledges the call.

Selector 7: Line connection timing

If a line is connected in a ringer-ON period, FAX models equipped with SDAA circuits may malfunction due to the ringer voltage. To make the line connection stable, this selector should be set to "0" so that a line is connected in a ringer-OFF period.

App. 1-18

Confidential