9.46Scanner Unit ASSY
(1)Disconnect the connector of the Scanner motor harness from the Driver PCB.
(2)Disconnect the connector of the Photo interrupter and FFC cable from the Main PCB.
Note:
•After disconnecting flat cable(s), check that each cable is not damaged at its end or
•When connecting flat cable(s), do not insert them at an angle. After insertion, check that the cables are not at an angle.
Driver PCB
Driver PCB
Scanner motor harness
FFC cable |
|
Photo interrupter |
|
Main PCB | Main PCB |
Fig.
(3)Remove the two cup B M4x20 Taptite screws. Lift up the rear of the Scanner unit slightly and remove the Scanner unit.
Taptite cup B M4x20 | Scanner unit |
Taptite cup B M4x20
Hook
3a
3b
Hook
Fig.
Confidential |