9.46Scanner Unit ASSY

(1)Disconnect the connector of the Scanner motor harness from the Driver PCB.

(2)Disconnect the connector of the Photo interrupter and FFC cable from the Main PCB.

Note:

After disconnecting flat cable(s), check that each cable is not damaged at its end or short-circuited.

When connecting flat cable(s), do not insert them at an angle. After insertion, check that the cables are not at an angle.

Driver PCB

Driver PCB

Scanner motor harness

FFC cable

 

Photo interrupter

 

Main PCB

Main PCB

Fig. 5-96

(3)Remove the two cup B M4x20 Taptite screws. Lift up the rear of the Scanner unit slightly and remove the Scanner unit.

Taptite cup B M4x20

Scanner unit

Taptite cup B M4x20

Hook

3a

3b

Hook

Fig. 5-97

5-82