■All black
Step | Cause | Check | Result | Remedy | |
|
|
|
|
| |
|
|
|
|
| |
| Corona wire | Are the electrodes on |
| Clean both electrodes. | |
1 | failure | the drum unit and | Yes | ||
|
| machine body dirty? |
|
| |
|
|
|
|
| |
2 |
| Is the corona wire | Yes | Replace the drum unit. | |
| damaged? |
| |||
|
|
|
| ||
|
|
|
|
| |
| Scanner harness | Is the scanner harness |
| Reconnect the scanner | |
3 | of the laser unit | of the laser unit | No | harness of the laser unit. | |
connection | connected securely? |
| |||
|
|
| |||
| failure |
|
|
| |
|
|
|
|
| |
| FG harness | Is the FG harness ASSY |
| Reconnect the FG harness | |
4 | ASSY connection | between the laser unit | No | ASSY between the laser | |
failure | and main PCB ASSY | unit and main PCB ASSY | |||
|
| ||||
|
| connected securely? |
| securely. | |
|
|
|
|
| |
| HVPS PCB | Is the problem solved |
| Replace the HVPS PCB | |
5 | failure | after replacing the | Yes | ASSY. | |
|
| HVPS PCB ASSY? |
|
| |
|
|
|
|
| |
| Main PCB failure | Is the problem solved |
| Replace the main PCB | |
6 |
| after replacing the main | Yes | ASSY. | |
|
| PCB ASSY? |
|
| |
|
|
|
|
| |
| Laser unit failure | Is the problem solved |
| Replace the laser unit. | |
7 |
| after replacing the laser | Yes |
| |
|
| unit? |
|
| |
|
|
|
|
|
Confidential |