<WSW34>
Selector No. | Function |
| Setting and Specifications | |||
|
|
|
|
|
| |
|
| No. 1 | 2 | 3 |
| |
| Erasing time length of ICM tone | 0 | 0 | 0: 0 sec. | ||
| 0 | 0 | 1: 1 sec. | |||
1 | recorded preceding the tone | |||||
detection starting point in the | 0 | 1 | 0: 2 sec. | |||
| ||||||
I | case of automatic line | 0 | 1 | 1: 3 sec. | ||
3 | disconnection due to no voice | 1 | 0 | 0: 4 sec. | ||
signal received | 1 | 0 | 1: 5 sec. | |||
| ||||||
| (Not used.) | 1 | 1 | 0: 6 sec. | ||
|
| |||||
|
| 1 | 1 | 1: 7 sec. | ||
|
|
| ||||
|
| In the case of Selector 6=0 in WSW58. | ||||
|
| No. 4 | 5 |
|
| |
| No. of CNG cycles to be | 0 | 0: 0.5 | (A) | ||
| 0 | 1: 1 | (B) | |||
| detected | |||||
| 1 | 0: 1.5 | (C) | |||
4 | (when the line is connected via | |||||
1 | 1: 2 | (D) | ||||
the external telephone in the | ||||||
5 | In the case of Selector 6=1 in WSW58. | |||||
external TAD mode or via the | ||||||
| No. 4 | 5 |
|
| ||
| machine in F/T mode) |
|
| |||
| 0 | 0: 2.5 | (A) | |||
| (Not used.) | |||||
| 0 | 1: 3 | (B) | |||
|
| |||||
|
| 1 | 0: 3.5 | (C) | ||
|
| 1 | 1: 4 | (D) | ||
|
|
|
|
|
| |
| Number of DTMF tone signals | No. 6 | 7 |
|
| |
6 | for inhibiting the detection of | 0 | 0: 3 |
| ||
CNG during external TAD | 0 | 1: 2 |
| |||
7 |
| |||||
operation | 1 | 0: 1 |
| |||
|
| |||||
| (Not used.) | 1 | 1: OFF |
| ||
|
|
|
|
|
| |
8 | Not used. |
|
|
|
| |
|
|
|
|
|
|
App. | Confidential |