■Faulty registration
1. ADF
Step | Cause | Check | Result | Remedy |
|
|
|
|
|
| Document rear | Does the document rear |
| |
1 | actuator catching | actuator move | No | rear actuator. |
| on some position | smoothly? |
|
|
|
|
|
|
|
| Fine adjustment | Is the problem solved by |
| Perform the fine |
| of scan start | performing the fine |
| adjustment of scan start |
2 | position | adjustment of scan start | Yes | position. |
| misalignment | position. |
| (Function code 54) |
|
| (Function code 54) |
|
|
|
|
|
|
|
2. Document table |
|
|
| |
|
|
|
|
|
Step | Cause | Check | Result | Remedy |
|
|
|
|
|
|
|
|
|
|
| Fine adjustment | Is the problem solved by |
| Perform the fine |
| of scan start | performing the fine |
| adjustment of scan start |
1 | position | adjustment of scan start | Yes | position. |
| misalignment | position. |
| (Function code 54) |
|
| (Function code 54) |
|
|
|
|
|
|
|
2 | CCD unit failure | Is the problem solved by | Yes | Replace the CCD unit. |
| replacing the CCD unit. |
| ||
|
|
|
| |
|
|
|
|
|
■ Dark
<User Check>
- Check whether the setting of the contrast does not become dark.
Step | Cause | Check | Result | Remedy |
|
|
|
|
|
|
|
|
|
|
| White level data | Is the problem solved by |
| Perform the acquisition of |
1 | malfunction | performing the | Yes | white level data. (Function |
| acquisition of white level | code 55) | ||
|
|
| ||
|
| data. (Function code 55) |
|
|
|
|
|
|
|
2 | CCD unit failure | Is the problem solved by | Yes | Replace the CCD unit. |
| replacing the CCD unit. |
| ||
|
|
|
| |
|
|
|
|
|
3 | Main PCB failure | Is the problem solved by | Yes | Replace the main PCB. |
| replacing the main PCB. |
| ||
|
|
|
| |
|
|
|
|
|
Confidential |