■Error code 76
Print Unable 76
Turn the power off and then back on again.
Rapid temperature rising failure (center thermistor)
Error code 78
Print Unable 78
Turn the power off and then back on again.
Rapid temperature falling failure (center thermistor)
Step | Cause | Remedy |
|
|
|
1 | Fuser unit failure | Replace the fuser unit. |
|
|
|
2 | Main PCB failure | Replace the main PCB ASSY. |
|
|
|
■Error code 7A
Print Unable 7A
See Troubleshooting and routine maintenance chapter in User's Guide.
No detection of main motor synchronous signal
Step | Cause | Remedy |
|
|
|
1 | Motor failure | Replace the main motor. |
|
|
|
2 | Main PCB failure | Replace the main PCB ASSY. |
|
|
|
■Error code 7D
Drum Error
Open the Front Cover and slide the blue tab across the Drum Unit several times.
Dirt on charged wire (detect discharge error)
User Check
•Clean the corona wire in the drum unit.
•Replace the drum unit with a new one.
Step | Cause | Remedy | |
|
|
| |
|
|
| |
1 | Dirt or dust on drum unit | Clean the electrodes of the main body and | |
electrodes | |||
| |||
|
|
| |
2 | Charge HVPS PCB failure | Replace the charge HVPS PCB ASSY. | |
|
|
| |
3 | Main PCB failure | Replace the main PCB ASSY. | |
|
|
|
Confidential |