9.TROUBLESHOOTING OF THE CONTROL PANEL

Nothing is displayed on the LCD.

<User Check>

- Verify if the power switch is turned off.

Step

Possible cause

Check

Result

Remedy

 

 

 

 

 

 

 

 

 

 

 

Connection

Are the main PCB and

 

Reconnect the connector

1

between main

control panel PCB

No

properly.

PCB and control

connected properly?

 

 

 

 

 

panel PCB

 

 

 

 

 

 

 

 

 

Harness

Is the harness

 

Replace the harness with a

2

between main

damaged?

Yes

normal one.

PCB and control

 

 

 

 

 

 

 

panel PCB

 

 

 

 

 

 

 

 

 

Connection

Are the main PCB and

 

Reconnect the connector

3

between main

PS PCB unit connected

No

properly.

PCB and PS

properly?

 

 

 

 

 

PCB unit

 

 

 

 

 

 

 

 

 

Harness

Is the harness

 

Replace the harness with a

4

between main

damaged?

Yes

normal one.

PCB and PS

 

 

 

 

 

 

 

PCB unit

 

 

 

 

 

 

 

 

5

LCD

Is the problem solved

Yes

Replace the LCD.

 

after replacing the LCD?

 

 

 

 

 

 

 

 

 

 

 

Control panel

Is the problem solved

 

Replace the control panel

6

PCB

after replacing the

Yes

PCB.

 

 

control panel PCB?

 

 

 

 

 

 

 

 

PS PCB unit

Is the problem solved

 

Replace the PS PCB unit.

7

 

after replacing the PS

Yes

 

 

 

PCB unit?

 

 

 

 

 

 

 

 

Main PCB

Is the problem solved

 

Replace the main PCB

8

 

after replacing the main

Yes

ASSY.

 

 

PCB ASSY?

 

 

 

 

 

 

 