<Function>
If connect with the
•USBNo.=ON: ON: Return to the serial number of the machine.
•USBNo.=OFF: Return to the "0".
<Operating Procedure>
(1)Press the [4] and [5] keys in this order in the initial stage of the maintenance mode. The “USBNo.=ON” will appear on the LCD.
(2)Press the [OK] button. and select the “USBNo. = ON” or “USBNo. = OFF” by pressing
the [] or [
] button. And press the [OK] or [Start] button. The machine beeps for approx. one second, and return to the initial stage of the maintenance mode.